CSI SECTIONFORMAT PDF

It is CSI’s recommended organization of information within an individual specification section. The consistency introduced by following SectionFormat promotes. About CSI: The Construction Specifications Institute is a professional association MasterFormat,™ SectionFormat™, PageFormat™, UniFormat™, National. Enter CSC/CSI SectionFormat. SectionFormat subscribes to the theory all requirements found in a specification can be organized into one of.

Author: Shalkis Maukasa
Country: Sao Tome and Principe
Language: English (Spanish)
Genre: Spiritual
Published (Last): 20 November 2014
Pages: 304
PDF File Size: 14.17 Mb
ePub File Size: 15.76 Mb
ISBN: 414-3-16827-165-9
Downloads: 67775
Price: Free* [*Free Regsitration Required]
Uploader: Zulukasa

The treatment of tables and schedules depends on the space available and the size of the table.

eectionformat Article titles are in uppercase font with no end punctuation. Define the tests performed in the field or at setcionformat site for verifying quality assurance for materials, systems, or assemblies. Describe specific approvals required by Authorities Having Jurisdiction relating to sustainability. Project name Project location Project number Issue date Package or phase identification Revision number The other area should contain section identification and other section-specific information that would not change from project to project.

SectionFormat and PageFormat |

ASTM A, standard masonry type; clean, dry; protected from dampness, freezing, or foreign matter. When only one of the subordinate titles is required, this Article title may be sedtionformat and the subordinate title may be used alone as a primary Article title. If desired, include an appropriate list of entities that make or sell the products specified. The only mandatory information is the section title, section number, eectionformat page number.

Skip auxiliary navigation Press Enter. Tables can be placed in Part 2 or at the end of Part 3. It does not assume that any particular technology will be used to produce the format outlined in this document.

  GRANDES SOBRAS BETO ORTIZ PDF

Operation and Maintenance Data: Underlining text should be avoided according to PageFormat. Identify the type and quantity here, but include the actual characteristics of the materials in Part 2.

SectionFormat/PageFormat

Provide a complete fully addressable, power limited, fire detection and evacuation system. Left edge binding is recommended as opposed to top edge binding. Albert Barton 1 years sectionfkrmat Views: For section information, the most important items are section title, section number, and page number.

This Article may be used to include final cleaning or building flush-out of sustainable products that are required to meet specific regulatory requirements or design criteria. Coordinate with work shown in other sections so the work is installed. Refer to Section Cast-In-Place Concrete for general concrete requirements, except as otherwise noted. Design based on products manufactured by The Fountain Experts 2. One part of a font size definition is the height of the line; the default value used by the processing system, or one point larger, is recommended for optimum readability.

SectionFormat/ PageFormat. The Recommended Format for Construction Specifications Sections

A logical indentation scheme should always be used. Section number Section title PF.

MasterFormat Subgroups may be identified in the Project Manual by labeled dividers or by dividing into separate volumes. Start display at page:. All submittals are optional; specify only the submittals justified by the project type and type of work covered by the section.

Coordinate terminology with contract language. Do not use anti-freeze compounds to lower the freezing point of mortar. SectionFormat Articles are optional and should be included in a section only as required to describe the information being presented. Overall construction cleaning should be addressed in Division Each Paragraph may contain subparagraphs as needed. The general scope, size, format, and quantity of shop drawing submittals are procedural requirements, which should be specified in Division Describe submittal of test reports or evaluation service reports intended to document required tests, without repeating the test requirements which should be specified elsewhere in Part 1, Part 2, or Part 3, as applicable.

  ALGI KAPILARI PDF

If the entity is a fabricator or other source such as a quarrythat term may be used instead of manufacturer. The location of key word generic product names in Article or paragraph titles may add to comprehension and emphasis.

Long or complex lists of Unit Prices may be appended as Attachments. If the “Action Submittals” Article is not used, the subordinate titles below should be located under the “Submittals” title. This Appendix describes exceptions to PageFormat that apply to pages displayed on a screen. With all the opinions, perhaps this could be a debate in itself during a future meeting.

BSD – CSI’s 3 Part Section Format

When the page number is combined with the section number, the exact page may be precisely referenced. Standardization and consistency are important objectives of any page format.

For qualified Installer and testing agency 1. Article titles should not be followed by text on the same line. List provisions for maintenance services as applicable to critical systems, equipment, and landscaping.